Assessment Year | 2021 |
---|---|
Principal Product | Air compressors, pumps, generators |
NAICS | 333912: Air and Gas Compressor Manufacturing |
SIC | 3563: Air and Gas Compressors |
Sales Range | $10 M to 50M |
# of Employees | 230 |
Plant Area |
206,500
ft2
|
Annual Production | 3,150
pieces
|
Production Hrs. Annual | 2,250
hrs
|
Location (State) | South Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $223,150 | 2,215,826 |
kWh
|
$0.10 | |
Electricity Demand | $35,187 | 6,207 |
kW-mo/yr
|
$5.67 | |
Electricity Fees | $8,500 | - |
|
- | |
Natural Gas | $15,215 | 16,783 |
MMBtu
|
$0.91 | |
Waste Disposal Costs | |||||
Water Usage | $15,349 | 835 |
Tgal
|
$18.38 | |
Water Disposal | $6,622 | 835 |
Tgal
|
$7.93 | |
TOTAL YEARLY COSTS | $304,023 | ||||
RECOMMENDED SAVINGS* | $27,380 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 4.454: Modify startup/shutdown times | $7,855 | $550 |
$7,855
78,000
kWh
|
- | |
02 | 2.2211: Use optimum temperature | $17,243 | - |
$17,243
171,223
kWh
|
- | |
03 | 2.7442: Keep doors and windows shut when not on use | $53 | - |
$53
527
kWh
|
- | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,229 | $4,600 |
$1,469
14,583
kWh
|
$760
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $27,380 | $5,150 |
$26,620
264,333
kWh
|
$760
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs