Assessment Year | 2019 |
---|---|
Principal Product | Liquid Flow Meters - Coriolis |
NAICS | 334519: Other Measuring and Controlling Device Manufacturing |
SIC | 3824: Totalizing Fluid Meters and Counting Devices |
Sales Range | $10 M to 50M |
# of Employees | 65 |
Plant Area |
127,755
ft2
|
Annual Production | 4,500
pieces
|
Production Hrs. Annual | 2,250
hrs
|
Location (State) | South Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $64,398 | 1,335,000 |
kWh
|
$0.048 | |
Electricity Demand | $72,930 | 5,772 |
kW-mo/yr
|
$12.64 | |
Electricity Fees | $1,602 | - |
|
- | |
Natural Gas | $12,030 | 1,760,100 |
MMBtu
|
$0.007 | |
Waste Disposal Costs | |||||
Water Usage | $3,923 | 98 |
Tgal
|
$40.03 | |
Water Disposal | $5,379 | 98 |
Tgal
|
$54.66 | |
TOTAL YEARLY COSTS | $160,262 | ||||
RECOMMENDED SAVINGS* | $20,835 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $20,835 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.7111: Reduce illumination to minimum necessary levels | $4,261 | $6,500 |
$1,713
35,700
kWh
|
$2,548
-
kW-mo/yr
|
|
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $918 | $2,080 |
$369
7,693
kWh
|
$549
-
kW-mo/yr
|
|
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $5,441 | - |
$2,188
45,581
kWh
|
$3,253
-
kW-mo/yr
|
|
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,586 | $1,600 |
$1,076
22,410
kWh
|
$1,511
-
kW-mo/yr
|
|
05 | 2.7444: Close holes and openings in building such as broken windows | $139 | $900 |
$139
2,903
kWh
|
- | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,489 | $13,085 |
$3,224
67,164
kWh
|
$4,265
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $20,835 | $24,165 |
$8,709
181,451
kWh
|
$12,126
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $20,835 | $24,165 |
$8,709
181,451
kWh
|
$12,126
-
kW-mo/yr
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs