Assessment Year | 2019 |
---|---|
Principal Product | Wheeled loaders, forklifts |
NAICS | 333120: Construction Machinery Manufacturing |
SIC | 3531: Construction Machinery and Equipment |
Sales Range | $10 M to 50M |
# of Employees | 220 |
Plant Area |
250,000
ft2
|
Annual Production | 4,000
units
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | South Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $113,138 | 2,934,799 |
kWh
|
$0.039 | |
Electricity Demand | $77,117 | 4,924 |
kW-mo/yr
|
$15.66 | |
Electricity Fees | $40,879 | - |
|
- | |
Natural Gas | $79,300 | 8,300 |
MMBtu
|
$9.55 | |
Waste Disposal Costs | |||||
Water Usage | $7,200 | 529 |
Tgal
|
$13.61 | |
Water Disposal | $10,800 | 529 |
Tgal
|
$20.42 | |
TOTAL YEARLY COSTS | $328,434 | ||||
RECOMMENDED SAVINGS* | $44,470 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $44,470 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $29,975 | $18,832 |
$14,282
366,212
kWh
|
$15,693
-
kW-mo/yr
|
|
02 | 2.6218: Turn off equipment when not in use | $48 | - |
$48
1,238
kWh
|
- | |
03 | 2.4226: Use / purchase optimum sized compressor | $14,447 | $39,883 |
$14,447
370,440
kWh
|
- | |
TOTAL RECOMMENDED | $44,470 | $58,715 |
$28,777
737,890
kWh
|
$15,693
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $44,470 | $58,715 |
$28,777
737,890
kWh
|
$15,693
-
kW-mo/yr
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs