| Assessment Year | 2019 |
|---|---|
| Principal Product | Automotive subframes & instrument panels |
| NAICS | 336340: Motor Vehicle Brake System Manufacturing |
| SIC | 3714: Motor Vehicle Parts and Accessories |
| Sales Range | $1 M to 5M |
| # of Employees | 400 |
| Plant Area |
265,000
ft2
|
| Annual Production | 10,000
units
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | South Carolina |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $123,081 | 3,608,078 |
kWh
|
$0.034 |
| Electricity Demand | $89,249 | 8,142 |
kW-mo/yr
|
$10.96 |
| TOTAL YEARLY COSTS | $212,330 | |||
| RECOMMENDED SAVINGS* | $17,812 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $17,812 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $12,368 | $13,023 |
$7,131
198,082
kWh
|
$5,237
-
kW-mo/yr
|
|
| 02 | 2.7442: Keep doors and windows shut when not on use | $1,260 | - |
$1,260
34,992
kWh
|
- | |
| 03 | 2.3132: Recharge batteries on during off-peak demand periods | $4,184 | - |
$1,224
-
kWh
|
$2,960
-
kW-mo/yr
|
|
| TOTAL RECOMMENDED | $17,812 | $13,023 |
$9,615
233,074
kWh
|
$8,197
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | $17,812 | $13,023 |
$9,615
233,074
kWh
|
$8,197
-
kW-mo/yr
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs