| Assessment Year | 2025 |
|---|---|
| Principal Product | Aluminum Door Assemblies |
| NAICS | 332321: Metal Window and Door Manufacturing |
| SIC | 3442: Metal Doors, Sash, Frames, Molding, and Trim Manufacturing |
| Sales Range | $100 M to 500M |
| # of Employees | 150 |
| Plant Area |
225,000
ft2
|
| Annual Production | 1,000,000
units
|
| Production Hrs. Annual | 4,160
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $110,895 | 2,607,470 |
kWh
|
$0.043 |
| Electricity Demand | $190,747 | 11,112 |
kW-mo/yr
|
$17.17 |
| Electricity Fees | $9,311 | - |
|
- |
| Natural Gas | $54,265 | 73,118 |
MMBtu
|
$0.74 |
| LPG | $18,720 | 570 |
MMBtu
|
$32.84 |
| Other Gas | $12,580 | 1 |
MMBtu
|
$12,580.00 |
| TOTAL YEARLY COSTS | $396,518 | |||
| RECOMMENDED SAVINGS* | $303,432 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.9114: Use solar heat to make electricty | $137,124 | $2,475,400 |
$79,433
1,869,000
kWh
|
$57,691
-
kW-mo/yr
|
- | - | |
| 02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $29,714 | $120,000 |
$13,729
323,024
kWh
|
$15,985
-
kW-mo/yr
|
- | - | |
| 03 | 2.3137: Use power during off-peak periods | $21,519 | $29,320 | - |
$21,519
-
kW-mo/yr
|
- | - | |
| 04 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $21,062 | $108,200 |
$21,062
495,583
kWh
|
- | - | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $22,882 | $40,000 |
$9,278
218,310
kWh
|
$8,104
-
kW-mo/yr
|
- | $5,500 | |
| 06 | 2.8227: Adjust / maintain fork lift trucks for most efficient operation | $15,715 | $48,000 |
$(-1,008.0)
(-23,712)
kWh
|
$(-1,997.0)
-
kW-mo/yr
|
$18,720
-
MMBtu
|
- | |
| 07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $13,846 | $4,700 |
$7,786
183,205
kWh
|
$6,060
-
kW-mo/yr
|
- | - | |
| 08 | 2.7447: Install vinyl strip / high speed / air curtain doors | $12,880 | $48,000 |
$2,480
58,350
kWh
|
- | - | $10,400 | |
| 09 | 2.7135: Install occupancy sensors | $7,744 | $22,500 |
$3,929
92,450
kWh
|
$3,815
-
kW-mo/yr
|
- | - | |
| 10 | 2.4239: Eliminate or reduce compressed air usage | $6,999 | - |
$6,999
164,681
kWh
|
- | - | - | |
| 11 | 2.7493: Use double or triple glazed windows to maintain higher relative humidity and to reduce heat losses | $5,540 | $18,000 |
$5,540
130,374
kWh
|
- | - | - | |
| 12 | 2.4239: Eliminate or reduce compressed air usage | $4,451 | $30,000 |
$4,451
104,738
kWh
|
- | - | - | |
| 13 | 2.3132: Recharge batteries on during off-peak demand periods | $3,956 | $12,000 | - |
$3,956
-
kW-mo/yr
|
- | - | |
| TOTAL RECOMMENDED | $303,432 | $2,956,120 |
$153,679
3,616,003
kWh
|
$115,133
-
kW-mo/yr
|
$18,720
-
MMBtu
|
$15,900 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs