Assessment Year | 1991 |
---|---|
Principal Product | CENTRIFUGAL PUMPS |
NAICS |
n/a
|
SIC | 3561: Pumps and Pumping Equipment |
Sales Range | $10 M to 50M |
# of Employees | 160 |
Plant Area |
n/a
|
Annual Production | 0
units
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $100,092 | 1,807,151 |
kWh
|
$0.055 |
Natural Gas | $18,837 | 4,462 |
MMBtu
|
$4.22 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $7,504 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $7,504 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.6124: Establish equipment maintenance schedule | $802 | - |
$770
4,103
kWh
|
- | $32 | |
02 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $1,152 | - |
$1,152
-
kWh
|
- | - | |
03 | 2.4239: Eliminate or reduce compressed air usage | $3,524 | $2,000 |
$4,279
110,785
kWh
|
$(-755.0)
-
MMBtu
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,026 | - |
$1,856
27,257
kWh
|
- | $170 | |
TOTAL RECOMMENDED | $7,504 | $2,000 |
$8,057
142,145
kWh
|
$(-755.0)
-
MMBtu
|
$202 | ||
TOTAL IMPLEMENTED | $7,504 | $2,000 |
$8,057
142,145
kWh
|
$(-755.0)
-
MMBtu
|
$202 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs