ITAC Assessment: CI0040
ITAC logo
ITAC Assessment: CI0040
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2025
Principal Product Supermarket Display Fixtures
NAICS 337215: Showcase, Partition, Shelving, and Locker Manufacturing
SIC 2541: Wood Office and Store Fixtures, Partitions, Shelving, and Lockers
Sales Range $10
M
to 50
M
# of Employees 65
Plant Area 18,500
ft2
Annual Production 18,000,000
pieces
Production Hrs. Annual 6,120
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $71,835 317,446
kWh
Electricity Demand $40,077 3,216
kW-mo/yr
Electricity Fees $10,759 -
Natural Gas $131 9
MMBtu
LPG $9,180 428
MMBtu
Other Gas $206 1
MMBtu
TOTAL YEARLY COSTS $132,188
RECOMMENDED SAVINGS* $132,418 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings LPG Savings Administrative Changes Savings Ancillary Material Cost Savings Increase in Production Savings
01 2.9114: Use solar heat to make electricty $57,161 $288,868 $52,210
230,710
kWh
$4,951
-
kW-mo/yr
- - - -
02 2.2622: Replace existing chiller with high efficiency model $34,278 $75,000 $34,278
151,470
kWh
- - - - -
03 2.4322: Use or replace with energy efficient substitutes $21,951 $31,000 $21,951
97,002
kWh
- - - - -
04 2.8227: Adjust / maintain fork lift trucks for most efficient operation $7,997 $19,000 $(-763.0)
(-3,370)
kWh
$(-420.0)
-
kW-mo/yr
$9,180
-
MMBtu
- - -
05 2.7134: Use photocell controls $5,246 $7,920 $3,890
17,191
kWh
$885
-
kW-mo/yr
- $213 $258 -
06 2.4226: Use / purchase optimum sized compressor $2,911 $6,699 $(-16,089.0)
(-71,096)
kWh
- - - - $19,000
07 2.7493: Use double or triple glazed windows to maintain higher relative humidity and to reduce heat losses $2,874 $7,990 $2,874
12,698
kWh
- - - - -
TOTAL RECOMMENDED $132,418 $436,477 $98,351
434,605
kWh
$5,416
-
kW-mo/yr
$9,180
-
MMBtu
$213 $258 $19,000
TOTAL IMPLEMENTED - - - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings LPG Savings Administrative Changes Savings Ancillary Material Cost Savings Increase in Production Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs