| Assessment Year | 2024 |
|---|---|
| Principal Product | Table Linen Manufacturing |
| NAICS | 313310: Textile and Fabric Finishing Mills |
| SIC | 2299: Textile goods, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 95 |
| Plant Area |
57,000
ft2
|
| Annual Production | 100,000
pieces
|
| Production Hrs. Annual | 1,664
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $42,845 | 352,920 |
kWh
|
$0.12 | |
| Electricity Demand | $18,596 | 1,551 |
kW-mo/yr
|
$11.99 | |
| Electricity Fees | $14,067 | - |
|
- | |
| Natural Gas | $64,552 | 6,455 |
MMBtu
|
$10.00 | |
| Waste Disposal Costs | |||||
| Water Usage | $23,155 | 4,229,940 |
Tgal
|
$0.005 | |
| TOTAL YEARLY COSTS | $163,215 | ||||
| RECOMMENDED SAVINGS* | $66,904 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.9114: Use solar heat to make electricty | $21,581 | $101,332 |
$18,298
150,726
kWh
|
$3,283
-
kW-mo/yr
|
- | |
| 02 | 2.2113: Repair or replace steam traps | $15,868 | $1,600 | - | - |
$15,868
-
MMBtu
|
|
| 03 | 2.7135: Install occupancy sensors | $8,384 | $3,000 |
$5,021
41,367
kWh
|
$3,363
-
kW-mo/yr
|
- | |
| 04 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $4,601 | $18,900 | - | - |
$4,601
-
MMBtu
|
|
| 05 | 2.2511: Insulate bare equipment | $4,265 | $2,565 | - | - |
$4,265
-
MMBtu
|
|
| 06 | 2.4133: Use most efficient type of electric motors | $3,914 | $1,600 |
$2,017
16,617
kWh
|
$1,897
-
kW-mo/yr
|
- | |
| 07 | 2.7134: Use photocell controls | $3,830 | $1,500 |
$1,168
9,620
kWh
|
$2,662
-
kW-mo/yr
|
- | |
| 08 | 2.2135: Repair and eliminate steam leaks | $2,431 | $4,000 | - | - |
$2,431
-
MMBtu
|
|
| 09 | 2.2437: Recover waste heat from equipment | $2,030 | $5,000 | - | - |
$2,030
-
MMBtu
|
|
| TOTAL RECOMMENDED | $66,904 | $139,497 |
$26,504
218,330
kWh
|
$11,205
-
kW-mo/yr
|
$29,195
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs