Assessment Year 2023
Principal Product PVC and CPVC Piping
NAICS 326122: Plastics Pipe and Pipe Fitting Manufacturing
SIC 3084: Plastics Pipe
Sales Range $10
M
to 50
M
# of Employees 37
Plant Area 166,000
ft2
Annual Production 19,000,000
lb
Production Hrs. Annual 6,000
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $512,777 2,110,307
kWh
Natural Gas $124,876 26,095
MMBtu
LPG $96,000 395
MMBtu
Waste Disposal Costs
Water Usage $3,196 2,038
Tgal
TOTAL YEARLY COSTS $736,849
RECOMMENDED SAVINGS* $235,117 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings LPG Savings
01 2.9114: Use solar heat to make electricty $92,262 $487,880 $92,262
379,680
kWh
- -
02 2.1321: Replace fossil fuel equipment with electrical equipment $76,570 $180,000 $(-19,430.0)
(-79,960)
kWh
- $96,000
-
MMBtu
03 2.2437: Recover waste heat from equipment $55,349 $45,000 $55,349
227,774
kWh
- -
04 2.4133: Use most efficient type of electric motors $6,503 $2,870 $6,503
26,666
kWh
- -
05 2.4226: Use / purchase optimum sized compressor $3,187 $20,000 - $3,187
-
MMBtu
-
06 2.7134: Use photocell controls $1,246 $750 $1,246
5,088
kWh
- -
TOTAL RECOMMENDED $235,117 $736,500 $135,930
559,248
kWh
$3,187
-
MMBtu
$96,000
-
MMBtu
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings LPG Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs