ITAC Assessment: CI0009
ITAC logo
ITAC Assessment: CI0009
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2023
Principal Product Filters
NAICS 333413: Industrial and Commercial Fan and Blower and Air Purification Equipment Manufacturing
SIC 3564: Industrial and Commercial Fans and Blowers and Air Purification Equipment
Sales Range $10
M
to 50
M
# of Employees 120
Plant Area 125,000
ft2
Annual Production 4,500,000
pieces
Production Hrs. Annual 4,680
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $62,670 761,333
kWh
Electricity Demand $43,804 1,983
kW-mo/yr
Natural Gas $43,092 2,862
MMBtu
TOTAL YEARLY COSTS $149,566
RECOMMENDED SAVINGS* $97,871 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.9114: Use solar heat to make electricty $46,339 $196,478 $17,021
206,822
kWh
$29,318
-
kW-mo/yr
02 2.7447: Install vinyl strip / high speed / air curtain doors $11,591 $41,000 $11,591
140,850
kWh
-
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $11,199 $1,500 $7,386
89,749
kWh
$3,813
-
kW-mo/yr
04 2.7142: Utilize higher efficiency lamps and/or ballasts $10,281 $14,880 $5,698
69,232
kWh
$4,583
-
kW-mo/yr
05 2.4239: Eliminate or reduce compressed air usage $9,574 - $9,574
116,329
kWh
-
06 2.7135: Install occupancy sensors $4,832 $4,725 $2,678
32,545
kWh
$2,154
-
kW-mo/yr
07 2.7134: Use photocell controls $4,055 $2,500 $1,188
14,439
kWh
$2,867
-
kW-mo/yr
TOTAL RECOMMENDED $97,871 $261,083 $55,136
669,966
kWh
$42,735
-
kW-mo/yr
TOTAL IMPLEMENTED - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs