| Assessment Year | 2014 |
|---|---|
| Principal Product | Heating/Cooling Coils |
| NAICS | 333415: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipmen |
| SIC | 3585: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment |
| Sales Range | $10 M to 50M |
| # of Employees | 155 |
| Plant Area |
55,000
ft2
|
| Annual Production | 1,820
pieces
|
| Production Hrs. Annual | 4,188
hrs
|
| Location (State) | Washington |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $93,882 | 1,193,409 |
kWh
|
$0.079 |
| Electricity Demand | $27,618 | 4,091 |
kW-mo/yr
|
$6.75 |
| Electricity Fees | $314 | - |
|
- |
| Natural Gas | $37,766 | 4,743 |
MMBtu
|
$7.96 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $34,282 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $25,335 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,472 | $8,031 |
$2,059
26,061
kWh
|
$413
-
kW-mo/yr
|
- | |
| 02 | 2.4322: Use or replace with energy efficient substitutes | $17,441 | $42,000 |
$17,441
220,776
kWh
|
- | - | |
| 03 | 2.7243: Improve air circulation with destratification fans / other methods | $4,279 | $17,525 |
$(-398.2)
(-5,040)
kWh
|
- |
$4,677
-
MMBtu
|
|
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,955 | $450 |
$1,955
24,752
kWh
|
- | - | |
| 05 | 2.6212: Turn off equipment during breaks, reduce operating time | $1,973 | $3,120 |
$1,973
24,974
kWh
|
- | - | |
| 06 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $4,668 | $9,641 | - | - |
$4,668
-
MMBtu
|
|
| 07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,494 | $175 |
$1,494
18,907
kWh
|
- | - | |
| TOTAL RECOMMENDED | $34,282 | $80,942 |
$24,524
310,430
kWh
|
$413
-
kW-mo/yr
|
$9,345
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $25,335 | $53,776 |
$24,922
315,470
kWh
|
$413
-
kW-mo/yr
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs