| Assessment Year | 2022 |
|---|---|
| Principal Product | Metal retainer with rubber seals |
| NAICS | 336413: Other Aircraft Parts and Auxiliary Equipment Manufacturing |
| SIC | 3449: Miscellaneous Structural Metal Work |
| Sales Range | $10 M to 50M |
| # of Employees | 158 |
| Plant Area |
66,336
ft2
|
| Annual Production | 186,553
pieces
|
| Production Hrs. Annual | 5,616
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $135,941 | 2,366,759 |
kWh
|
$0.057 | |
| Electricity Demand | $244,010 | 10,887 |
kW-mo/yr
|
$22.41 | |
| Electricity Fees | $179,031 | - |
|
- | |
| Natural Gas | $8,233 | 287 |
MMBtu
|
$28.69 | |
| Waste Disposal Costs | |||||
| Water Usage | $16,625 | 987,360 |
Tgal
|
$0.017 | |
| TOTAL YEARLY COSTS | $583,840 | ||||
| RECOMMENDED SAVINGS* | $55,079 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $27,056 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $27,056 | $750 |
$13,473
236,360
kWh
|
$13,583
-
kW-mo/yr
|
- | - | |
| 02 | 2.2437: Recover waste heat from equipment | $16,299 | $3,500 |
$4,682
82,148
kWh
|
$11,617
-
kW-mo/yr
|
- | - | |
| 03 | 2.1122: Re-size charging openings or add a movable door on equipment | $5,122 | $6,000 |
$5,122
89,856
kWh
|
- | - | - | |
| 04 | 2.3132: Recharge batteries on during off-peak demand periods | $2,151 | $100 | - |
$2,151
-
kW-mo/yr
|
- | - | |
| 05 | 2.4226: Use / purchase optimum sized compressor | $2,000 | $5,000 |
$2,000
35,087
kWh
|
- | - | - | |
| 06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,304 | $25 |
$461
8,081
kWh
|
$843
-
kW-mo/yr
|
- | - | |
| 07 | 2.7134: Use photocell controls | $1,147 | $1,440 |
$345
6,050
kWh
|
$622
-
kW-mo/yr
|
$82 | $98 | |
| TOTAL RECOMMENDED | $55,079 | $16,815 |
$26,083
457,582
kWh
|
$28,816
-
kW-mo/yr
|
$82 | $98 | ||
| TOTAL IMPLEMENTED | $27,056 | $750 |
$13,473
236,360
kWh
|
$13,583
-
kW-mo/yr
|
- | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs