| Assessment Year | 2020 |
|---|---|
| Principal Product | Vegetable Seed |
| NAICS | 339999: All Other Miscellaneous Manufacturing |
| SIC | 3999: Manufacturing Industries, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 167 |
| Plant Area |
150,000
ft2
|
| Annual Production | 132,000,000
lb
|
| Production Hrs. Annual | 7,200
hrs
|
| Location (State) | Idaho |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $79,846 | 1,354,377 |
kWh
|
$0.059 |
| Electricity Demand | $33,493 | 6,456 |
kW-mo/yr
|
$5.19 |
| Electricity Fees | $1,816 | - |
|
- |
| Natural Gas | $84,641 | 17,934 |
MMBtu
|
$4.72 |
| Fuel Oil #2 | $37,567 | 1,541 |
MMBtu
|
$24.38 |
| Other Gas | $20,908 | 1,426 |
MMBtu
|
$14.66 |
| TOTAL YEARLY COSTS | $258,271 | |||
| RECOMMENDED SAVINGS* | $55,227 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Fuel Oil #2 Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,513 | $4,844 |
$1,077
18,270
kWh
|
$436
-
kW-mo/yr
|
- | - | |
| 02 | 2.4224: Upgrade controls on compressors | $2,100 | $3,760 |
$2,100
35,608
kWh
|
- | - | - | |
| 03 | 2.4226: Use / purchase optimum sized compressor | $25,951 | $77,377 |
$(-11,375.0)
(-192,924)
kWh
|
- | - |
$37,326
-
MMBtu
|
|
| 04 | 2.4133: Use most efficient type of electric motors | $10,213 | $4,620 |
$9,366
158,848
kWh
|
$847
-
kW-mo/yr
|
- | - | |
| 05 | 2.7273: Install desiccant humidity control system | $2,938 | $4,056 |
$2,938
49,834
kWh
|
- | - | - | |
| 06 | 2.4133: Use most efficient type of electric motors | $1,864 | $1,500 |
$1,864
31,593
kWh
|
- | - | - | |
| 07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,209 | $610 |
$754
12,790
kWh
|
$455
-
kW-mo/yr
|
- | - | |
| 08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $325 | $675 |
$81
1,368
kWh
|
$244
-
kW-mo/yr
|
- | - | |
| 09 | 2.9113: Use solar heat for heat | $9,114 | $35,799 | - | - |
$9,114
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $55,227 | $133,241 |
$6,805
115,387
kWh
|
$1,982
-
kW-mo/yr
|
$9,114
-
MMBtu
|
$37,326
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Fuel Oil #2 Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs