Assessment Year | 2019 |
---|---|
Principal Product | Milk |
NAICS | 311511: Fluid Milk Manufacturing |
SIC | 2026: Fluid Milk |
Sales Range | $50 M to 100M |
# of Employees | 57 |
Plant Area |
42,000
ft2
|
Annual Production | 18,000
Tgal
|
Production Hrs. Annual | 5,928
hrs
|
Location (State) | Idaho |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $168,234 | 3,495,193 |
kWh
|
$0.048 |
Electricity Demand | $61,154 | 9,313 |
kW-mo/yr
|
$6.57 |
Electricity Fees | $6,166 | - |
|
- |
Natural Gas | $66,463 | 13,101 |
MMBtu
|
$5.07 |
LPG | $4,942 | 122 |
MMBtu
|
$40.51 |
TOTAL YEARLY COSTS | $306,959 | |||
RECOMMENDED SAVINGS* | $41,626 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | LPG Savings | Water Usage Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $2,168 | $10,162 | - | - | $2,168 | - | - | - | |
02 | 2.4322: Use or replace with energy efficient substitutes | $143 | $260 |
$112
2,334
kWh
|
$31
-
kW-mo/yr
|
- | - | - | - | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $320 | $50 |
$183
3,809
kWh
|
$137
-
kW-mo/yr
|
- | - | - | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,903 | $4,567 |
$1,726
35,855
kWh
|
$177
-
kW-mo/yr
|
- | - | - | - | |
05 | 2.2113: Repair or replace steam traps | $7,006 | $5,147 | - | - | - |
$4,806
-
MMBtu
|
- |
$2,200
-
Tgal
|
|
06 | 2.4321: Upgrade obsolete equipment | $4,616 | $8,000 |
$(-323.0)
(-6,710)
kWh
|
- | - | - |
$4,939
-
MMBtu
|
- | |
07 | 2.1223: Install smaller boiler (increase high fire duty cycle) | $12,064 | $54,000 | - | - | - |
$12,064
-
MMBtu
|
- | - | |
08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $691 | $615 |
$691
14,357
kWh
|
- | - | - | - | - | |
09 | 2.4226: Use / purchase optimum sized compressor | $4,644 | $3,670 |
$4,644
96,489
kWh
|
- | - | - | - | - | |
10 | 2.4133: Use most efficient type of electric motors | $5,813 | $5,325 |
$5,032
104,559
kWh
|
$781
-
kW-mo/yr
|
- | - | - | - | |
11 | 2.2626: Avoid frost formation on evaporators | $2,258 | $618 |
$2,258
46,909
kWh
|
- | - | - | - | - | |
TOTAL RECOMMENDED | $41,626 | $92,414 |
$14,323
297,602
kWh
|
$1,126
-
kW-mo/yr
|
$2,168 |
$16,870
-
MMBtu
|
$4,939
-
MMBtu
|
$2,200
-
Tgal
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | LPG Savings | Water Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs