ITAC Assessment: BS0077
ITAC logo
ITAC Assessment: BS0077
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2016
Principal Product Encoders
NAICS 334519: Other Measuring and Controlling Device Manufacturing
SIC 3829: Measuring and Controlling Devices, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 135
Plant Area 100,800
ft2
Annual Production 110,000
pieces
Production Hrs. Annual 2,008
hrs
Location (State) Idaho

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $90,612 1,331,400
kWh
Electricity Demand $29,424 4,293
kW-mo/yr
TOTAL YEARLY COSTS $120,036
RECOMMENDED SAVINGS* $5,272 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $3,392

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.7423: Reduce heat gain by window tinting $1,622 $2,644 $1,622
23,860
kWh
-
02 2.7444: Close holes and openings in building such as broken windows $698 $505 $698
10,269
kWh
-
03 2.7142: Utilize higher efficiency lamps and/or ballasts $711 $960 $624
9,180
kWh
$86
-
kW-mo/yr
04 2.7142: Utilize higher efficiency lamps and/or ballasts $1,328 $3,080 $1,032
15,181
kWh
$296
-
kW-mo/yr
05 2.4221: Install compressor air intakes in coolest locations $141 $530 $141
2,082
kWh
-
06 2.4231: Reduce the pressure of compressed air to the minimum required $370 $15 $231
3,397
kWh
$139
-
kW-mo/yr
07 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $118 $47 $118
1,736
kWh
-
08 2.7233: Use properly designed and sized hvac equipment $117 $340 $117
1,713
kWh
-
09 2.4111: Utilize energy-efficient belts and other improved mechanisms $167 $400 $143
2,097
kWh
$25
-
kW-mo/yr
TOTAL RECOMMENDED $5,272 $8,521 $4,726
69,515
kWh
$546
-
kW-mo/yr
TOTAL IMPLEMENTED $3,392 $5,007 $2,846
41,860
kWh
$546
-
kW-mo/yr
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs