Assessment Year | 2015 |
---|---|
Principal Product | Water Filters |
NAICS | 333999: All Other Miscellaneous General Purpose Machinery Manufacturing |
SIC | 3589: Service Industry Machinery, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 144 |
Plant Area |
50,000
ft2
|
Annual Production | 1,500,000
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Idaho |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $142,887 | 2,897,181 |
kWh
|
$0.049 |
Electricity Demand | $62,309 | 9,648 |
kW-mo/yr
|
$6.46 |
Electricity Fees | $13,654 | - |
|
- |
Natural Gas | $34,017 | 4,599 |
MMBtu
|
$7.40 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $44,248 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $37,401 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $12,761 | $18,045 | - | - | $12,761 | |
02 | 2.4224: Upgrade controls on compressors | $5,532 | $1,105 |
$3,691
74,844
kWh
|
$1,841
-
kW-mo/yr
|
- | |
03 | 2.4221: Install compressor air intakes in coolest locations | $1,254 | $526 |
$918
18,611
kWh
|
$336
-
kW-mo/yr
|
- | |
04 | 2.4322: Use or replace with energy efficient substitutes | $744 | $264 |
$424
8,587
kWh
|
$320
-
kW-mo/yr
|
- | |
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $23,386 | $9,729 |
$15,553
315,339
kWh
|
$7,833
-
kW-mo/yr
|
- | |
06 | 2.7135: Install occupancy sensors | $178 | $91 |
$178
3,602
kWh
|
- | - | |
07 | 2.7212: Install or upgrade insulation on hvac distribution systems | $368 | $4,065 |
$368
7,464
kWh
|
- | - | |
08 | 2.7228: Avoid introducing hot, humid, or dirty air into hvac system | $25 | $929 |
$25
503
kWh
|
- | - | |
TOTAL RECOMMENDED | $44,248 | $34,754 |
$21,157
428,950
kWh
|
$10,330
-
kW-mo/yr
|
$12,761 | ||
TOTAL IMPLEMENTED | $37,401 | $28,300 |
$16,471
333,950
kWh
|
$8,169
-
kW-mo/yr
|
$12,761 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs