ITAC Assessment: BS0043
ITAC logo
ITAC Assessment: BS0043
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2014
Principal Product Frozen Seafood
NAICS 311710: Seafood Product Preparation and Packaging
SIC 2092: Prepared Fresh or Frozen Fish and Seafoods
Sales Range $50
M
to 100
M
# of Employees 325
Plant Area 80,000
ft2
Annual Production 200,000,000
lb
Production Hrs. Annual 7,488
hrs
Location (State) Alaska

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $982,181 7,223,440
kWh
Electricity Demand $118,051 19,199
kW-mo/yr
Electricity Fees $2,471 -
Fuel Oil #2 $324,138 11,576
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $245,457 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $193,256

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Fuel Oil #2 Savings
01 2.2621: Modify refrigeration system to operate at a lower pressure $63,855 $15,000 $63,855
469,524
kWh
- -
02 2.2511: Insulate bare equipment $8,916 $19,760 $7,146
52,542
kWh
$1,770
-
kW-mo/yr
-
03 2.1223: Install smaller boiler (increase high fire duty cycle) $111,915 $69,000 $(-38,759.0)
(-284,990)
kWh
$(-9,736.0)
-
kW-mo/yr
$160,410
-
MMBtu
04 2.6231: Utilize controls to operate equipment only when needed $13,411 $5,075 $13,411
98,610
kWh
- -
05 2.5121: Redesign flow to minimize mass transfer length $13,508 $17,493 $12,985
95,481
kWh
$523
-
kW-mo/yr
-
06 2.4111: Utilize energy-efficient belts and other improved mechanisms $4,075 $429 $4,075
29,963
kWh
- -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $23,042 $52,954 $21,695
159,520
kWh
$1,347
-
kW-mo/yr
-
08 2.7135: Install occupancy sensors $2,340 $981 $2,340
17,203
kWh
- -
09 2.7142: Utilize higher efficiency lamps and/or ballasts $3,381 $7,554 $3,381
24,859
kWh
- -
10 2.7142: Utilize higher efficiency lamps and/or ballasts $1,014 $1,242 $988
7,267
kWh
$26
-
kW-mo/yr
-
TOTAL RECOMMENDED $245,457 $189,488 $91,117
669,979
kWh
$(-6,070.0)
-
kW-mo/yr
$160,410
-
MMBtu
TOTAL IMPLEMENTED $193,256 $89,504 $42,582
313,107
kWh
$(-9,736.0)
-
kW-mo/yr
$160,410
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Fuel Oil #2 Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs