| Assessment Year | 2014 |
|---|---|
| Principal Product | Composite Structures |
| NAICS | 336413: Other Aircraft Parts and Auxiliary Equipment Manufacturing |
| SIC | 3728: Aircraft Parts and Auxiliary Equipment, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 145 |
| Plant Area |
59,300
ft2
|
| Annual Production | 48,000
pieces
|
| Production Hrs. Annual | 4,300
hrs
|
| Location (State) | Idaho |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $130,352 | 2,040,008 |
kWh
|
$0.064 |
| Electricity Demand | $33,574 | 6,896 |
kW-mo/yr
|
$4.87 |
| Natural Gas | $46,863 | 5,024 |
MMBtu
|
$9.33 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $19,625 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,789 | $8,520 |
$1,410
22,023
kWh
|
$1,379
-
kW-mo/yr
|
- | - | |
| 02 | 2.7135: Install occupancy sensors | $1,000 | $180 |
$727
11,365
kWh
|
- | - | $273 | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $988 | $5,580 |
$828
12,947
kWh
|
$160
-
kW-mo/yr
|
- | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $156 | $480 |
$156
2,448
kWh
|
- | - | - | |
| 05 | 2.6212: Turn off equipment during breaks, reduce operating time | $3,010 | $3,900 |
$3,010
47,038
kWh
|
- | - | - | |
| 06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,476 | $15 |
$1,337
20,886
kWh
|
$139
-
kW-mo/yr
|
- | - | |
| 07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $398 | $722 |
$398
6,218
kWh
|
- | - | - | |
| 08 | 2.4221: Install compressor air intakes in coolest locations | $930 | $285 |
$930
14,529
kWh
|
- | - | - | |
| 09 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $118 | $292 |
$118
1,846
kWh
|
- | - | - | |
| 10 | 2.2414: Use waste heat from hot flue gases to preheat | $8,324 | $15,600 |
$2,784
43,504
kWh
|
- |
$5,540
-
MMBtu
|
- | |
| 11 | 2.2511: Insulate bare equipment | $436 | $1,128 |
$436
6,810
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $19,625 | $36,702 |
$12,134
189,614
kWh
|
$1,678
-
kW-mo/yr
|
$5,540
-
MMBtu
|
$273 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs