ITAC Assessment: BS0009
ITAC logo
ITAC Assessment: BS0009
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2013
Principal Product Milk, Sour Cream, Cottage Cheese
NAICS 311511: Fluid Milk Manufacturing
SIC 2026: Fluid Milk
Sales Range $50
M
to 100
M
# of Employees 130
Plant Area 100,000
ft2
Annual Production 39,000
Tgal
Production Hrs. Annual 8,760
hrs
Location (State) Idaho

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $377,051 12,815,595
kWh
Electricity Demand $108,161 25,023
kW-mo/yr
Electricity Fees $77,479 -
Natural Gas $967,680 131,248
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $772,484 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $11,127

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings By-product Production Savings
01 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,591 $260 $1,591
51,415
kWh
- - -
02 2.6218: Turn off equipment when not in use $1,495 $1,840 $1,495
48,320
kWh
- - -
03 2.2437: Recover waste heat from equipment $1,533 $2,806 $(-59.4)
(-1,921)
kWh
- $1,592
-
MMBtu
-
04 2.4221: Install compressor air intakes in coolest locations $2,077 $689 $1,647
53,220
kWh
$430
-
kW-mo/yr
- -
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,037 $126 $2,037
65,843
kWh
- - -
06 2.2136: Install / repair insulation on steam lines $5,422 $3,959 - - $5,422
-
MMBtu
-
07 2.2136: Install / repair insulation on steam lines $3,187 $1,066 - - $3,187
-
MMBtu
-
08 2.7233: Use properly designed and sized hvac equipment $11,756 $210 $11,756
379,946
kWh
- - -
09 2.1336: Install equipment to utilize waste fuel $743,387 $1,700,000 - - - $743,387
TOTAL RECOMMENDED $772,484 $1,710,956 $18,467
596,823
kWh
$430
-
kW-mo/yr
$10,201
-
MMBtu
$743,387
TOTAL IMPLEMENTED $11,127 $5,034 $5,275
170,478
kWh
$430
-
kW-mo/yr
$5,422
-
MMBtu
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings By-product Production Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs