Assessment Year | 2017 |
---|---|
Principal Product | Agricultural Equipment |
NAICS | 333922: Conveyor and Conveying Equipment Manufacturing |
SIC | 3523: Farm Machinery and Equipment |
Sales Range | $10 M to 50M |
# of Employees | 66 |
Plant Area |
202,600
ft2
|
Annual Production | 5,000
units
|
Production Hrs. Annual | 2,340
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $109,293 | 2,109,033 |
kWh
|
$0.052 |
Electricity Demand | $84,581 | 9,846 |
kW-mo/yr
|
$8.59 |
Electricity Fees | $1,758 | - |
|
- |
Natural Gas | $95,466 | 23,330 |
MMBtu
|
$4.09 |
TOTAL YEARLY COSTS | $291,098 | |||
RECOMMENDED SAVINGS* | $21,762 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.1221: Replace obsolete burners with more efficient ones | $6,894 | $18,000 | - | - |
$6,894
-
MMBtu
|
- | - | |
02 | 2.7231: Use radiant heater for spot heating | $5,446 | $12,000 |
$1,025
19,793
kWh
|
$679
-
kW-mo/yr
|
$3,742
-
MMBtu
|
- | - | |
03 | 2.7135: Install occupancy sensors | $2,169 | $1,950 |
$953
18,400
kWh
|
$1,216
-
kW-mo/yr
|
- | - | - | |
04 | 2.7134: Use photocell controls | $2,112 | $3,000 |
$838
16,182
kWh
|
$1,069
-
kW-mo/yr
|
- | $137 | $68 | |
05 | 2.4133: Use most efficient type of electric motors | $1,978 | $4,040 |
$1,069
20,632
kWh
|
$909
-
kW-mo/yr
|
- | - | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,456 | $3,960 |
$787
15,186
kWh
|
$669
-
kW-mo/yr
|
- | - | - | |
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $803 | $21 |
$434
8,372
kWh
|
$369
-
kW-mo/yr
|
- | - | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $350 | $300 |
$172
3,329
kWh
|
$40
-
kW-mo/yr
|
- | $58 | $80 | |
09 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $294 | $550 |
$164
3,159
kWh
|
$130
-
kW-mo/yr
|
- | - | - | |
10 | 2.4221: Install compressor air intakes in coolest locations | $260 | $600 |
$141
2,712
kWh
|
$119
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $21,762 | $44,421 |
$5,583
107,765
kWh
|
$5,200
-
kW-mo/yr
|
$10,636
-
MMBtu
|
$195 | $148 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs