ITAC Assessment: BD0450
ITAC logo
ITAC Assessment: BD0450
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2014
Principal Product Plastic resin pellets
NAICS 488991: Packing and Crating
SIC 4783: Packing and Crating
Sales Range $100
M
to 500
M
# of Employees 250
Plant Area 323,700
ft2
Annual Production 0
units
Production Hrs. Annual 5,200
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $281,480 2,663,579
kWh
Natural Gas $120,525 14,142
MMBtu
LPG $59,953 2,910
MMBtu
Fuel Oil #2 $325,204 13,515
MMBtu
Other Gas $22,891 861
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $47,546 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $7,471

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Personnel Changes Savings Ancillary Material Cost Savings
01 2.7231: Use radiant heater for spot heating $19,966 $27,000 - $19,966
-
MMBtu
- -
02 2.7142: Utilize higher efficiency lamps and/or ballasts $16,234 $24,940 $15,981
151,204
kWh
- $119 $134
03 2.4221: Install compressor air intakes in coolest locations $2,837 $1,000 $2,837
26,844
kWh
- - -
04 2.4321: Upgrade obsolete equipment $2,486 $20 $2,486
23,522
kWh
- - -
05 2.7142: Utilize higher efficiency lamps and/or ballasts $2,148 $2,850 $2,105
19,918
kWh
- $12 $31
06 2.7142: Utilize higher efficiency lamps and/or ballasts $1,909 $1,025 $1,372
12,982
kWh
- $225 $312
07 2.7134: Use photocell controls $777 $450 $659
6,234
kWh
- $104 $14
08 2.4133: Use most efficient type of electric motors $461 $320 $461
4,357
kWh
- - -
09 2.7135: Install occupancy sensors $406 $750 $406
3,840
kWh
- - -
10 2.7142: Utilize higher efficiency lamps and/or ballasts $322 $143 $254
2,402
kWh
- $19 $49
TOTAL RECOMMENDED $47,546 $58,498 $26,561
251,303
kWh
$19,966
-
MMBtu
$479 $540
TOTAL IMPLEMENTED $7,471 $3,870 $7,428
70,284
kWh
- $12 $31
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Personnel Changes Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs