Assessment Year | 2014 |
---|---|
Principal Product | Cold headed fasteners |
NAICS | 332722: Bolt, Nut, Screw, Rivet, and Washer Manufacturing |
SIC | 3452: Bolts, Nuts, Screws, Rivets, and Washers |
Sales Range | $5 M to 10M |
# of Employees | 30 |
Plant Area |
37,000
ft2
|
Annual Production | 130,000,000
pieces
|
Production Hrs. Annual | 5,200
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $36,778 | 511,077 |
kWh
|
$0.072 |
Electricity Demand | $9,100 | 1,794 |
kW-mo/yr
|
$5.07 |
Electricity Fees | $457 | - |
|
- |
Natural Gas | $13,150 | 2,083 |
MMBtu
|
$6.31 |
LPG | $2,400 | 105 |
MMBtu
|
$22.92 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $19,313 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7231: Use radiant heater for spot heating | $4,810 | $9,600 |
$813
11,291
kWh
|
$150
-
kW-mo/yr
|
$3,847
-
MMBtu
|
- | - | |
02 | 2.4133: Use most efficient type of electric motors | $3,881 | $11,770 |
$3,339
46,370
kWh
|
$542
-
kW-mo/yr
|
- | - | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,828 | $600 |
$2,450
34,033
kWh
|
$378
-
kW-mo/yr
|
- | - | - | |
04 | 2.3132: Recharge batteries on during off-peak demand periods | $2,214 | $40 | - |
$2,214
-
kW-mo/yr
|
- | - | - | |
05 | 2.7111: Reduce illumination to minimum necessary levels | $2,189 | $1,040 |
$1,495
20,767
kWh
|
$243
-
kW-mo/yr
|
- | $361 | $90 | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,450 | $1,420 |
$1,247
17,322
kWh
|
$203
-
kW-mo/yr
|
- | - | - | |
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,065 | $20 |
$916
12,718
kWh
|
$149
-
kW-mo/yr
|
- | - | - | |
08 | 2.7135: Install occupancy sensors | $510 | $900 |
$317
4,405
kWh
|
$193
-
kW-mo/yr
|
- | - | - | |
09 | 2.4221: Install compressor air intakes in coolest locations | $366 | $800 |
$299
4,147
kWh
|
$67
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $19,313 | $26,190 |
$10,876
151,053
kWh
|
$4,139
-
kW-mo/yr
|
$3,847
-
MMBtu
|
$361 | $90 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs