Assessment Year | 2013 |
---|---|
Principal Product | Fabricated Metal Products |
NAICS | 333111: Farm Machinery and Equipment Manufacturing |
SIC | 3531: Construction Machinery and Equipment |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
77,648
ft2
|
Annual Production | 1
units
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $200,851 | 2,080,800 |
kWh
|
$0.097 |
Electricity Demand | $35,251 | 6,344 |
kW-mo/yr
|
$5.56 |
Electricity Fees | $1,945 | - |
|
- |
Natural Gas | $22,506 | 3,972 |
MMBtu
|
$5.67 |
LPG | $43,896 | 1,628 |
MMBtu
|
$26.96 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $96,705 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $52,687 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | LPG Savings | Personnel Changes Savings | Primary Raw Material Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $33,115 | $39,240 |
$29,210
302,608
kWh
|
$3,234
-
kW-mo/yr
|
- | - | $133 | - | $538 | - | |
02 | 2.8227: Adjust / maintain fork lift trucks for most efficient operation | $31,849 | $76,000 |
$(-12,047.0)
(-124,800)
kWh
|
- | - |
$43,896
-
MMBtu
|
- | - | - | - | |
03 | 2.8114: Change rate schedules or other changes in utility service | $18,262 | $15,000 | - | - | - | - | - | - | - | $18,262 | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $4,563 | $20 |
$4,108
42,554
kWh
|
$455
-
kW-mo/yr
|
- | - | - | - | - | - | |
05 | 2.7135: Install occupancy sensors | $4,430 | $2,257 |
$3,506
36,320
kWh
|
$924
-
kW-mo/yr
|
- | - | - | - | - | - | |
06 | 2.4221: Install compressor air intakes in coolest locations | $1,903 | $1,400 |
$1,713
17,742
kWh
|
$190
-
kW-mo/yr
|
- | - | - | - | - | - | |
07 | 2.2437: Recover waste heat from equipment | $1,310 | $2,000 | - | - |
$1,310
-
MMBtu
|
- | - | - | - | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,273 | $3,150 |
$1,171
12,131
kWh
|
$130
-
kW-mo/yr
|
- | - | - | $140 | $(-168.0) | - | |
TOTAL RECOMMENDED | $96,705 | $139,067 |
$27,661
286,555
kWh
|
$4,933
-
kW-mo/yr
|
$1,310
-
MMBtu
|
$43,896
-
MMBtu
|
$133 | $140 | $370 | $18,262 | ||
TOTAL IMPLEMENTED | $52,687 | $56,240 |
$29,210
302,608
kWh
|
$3,234
-
kW-mo/yr
|
$1,310
-
MMBtu
|
- | $133 | - | $538 | $18,262 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | LPG Savings | Personnel Changes Savings | Primary Raw Material Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs