| Assessment Year | 2012 |
|---|---|
| Principal Product | Aerospace parts |
| NAICS | 336413: Other Aircraft Parts and Auxiliary Equipment Manufacturing |
| SIC | 3728: Aircraft Parts and Auxiliary Equipment, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 65 |
| Plant Area |
135,000
ft2
|
| Annual Production | 18,500
pieces
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Illinois |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $162,084 | 3,020,495 |
kWh
|
$0.054 |
| Electricity Demand | $35,274 | 6,810 |
kW-mo/yr
|
$5.18 |
| Electricity Fees | $3,116 | - |
|
- |
| Natural Gas | $22,010 | 1,779 |
MMBtu
|
$12.37 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $43,802 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $40,254 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $661 | $966 |
$420
7,828
kWh
|
$240
-
kW-mo/yr
|
- | |
| 02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $889 | $10 |
$750
13,965
kWh
|
$139
-
kW-mo/yr
|
- | |
| 03 | 2.4221: Install compressor air intakes in coolest locations | $1,168 | $300 |
$985
18,350
kWh
|
$183
-
kW-mo/yr
|
- | |
| 04 | 2.2437: Recover waste heat from equipment | $38,469 | $5,000 | - | - |
$38,469
-
MMBtu
|
|
| 05 | 2.4314: Use synthetic lubricant | $1,301 | $500 |
$1,098
20,448
kWh
|
$203
-
kW-mo/yr
|
- | |
| 06 | 2.7135: Install occupancy sensors | $1,124 | $375 |
$918
17,092
kWh
|
$206
-
kW-mo/yr
|
- | |
| 07 | 2.7134: Use photocell controls | $190 | $50 |
$144
2,673
kWh
|
$46
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $43,802 | $7,201 |
$4,315
80,357
kWh
|
$1,017
-
kW-mo/yr
|
$38,469
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $40,254 | $6,341 |
$1,338
24,920
kWh
|
$446
-
kW-mo/yr
|
$38,469
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs