| Assessment Year | 2011 |
|---|---|
| Principal Product | Wheels, Bearings, Ball Transfers |
| NAICS | 333613: Mechanical Power Transmission Equipment Manufacturing |
| SIC | 3535: Conveyors and Conveying Equipment |
| Sales Range | $5 M to 10M |
| # of Employees | 50 |
| Plant Area |
80,000
ft2
|
| Annual Production | 12,729,895
pieces
|
| Production Hrs. Annual | 3,120
hrs
|
| Location (State) | Illinois |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $203,746 | 3,185,348 |
kWh
|
$0.064 |
| Electricity Demand | $54,231 | 8,931 |
kW-mo/yr
|
$6.07 |
| Electricity Fees | $11,515 | - |
|
- |
| Natural Gas | $135,435 | 25,697 |
MMBtu
|
$5.27 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $111,113 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (non-haz) Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.2314: Replace heat treating oven with more efficient unit | $12,465 | $60,000 | - | - |
$12,465
-
MMBtu
|
- | |
| 02 | 2.7231: Use radiant heater for spot heating | $30,750 | $20,000 | - | - |
$30,750
-
MMBtu
|
- | |
| 03 | 2.1113: Reduce combustion air flow to optimum | $2,470 | $4,000 |
$(-210.0)
(-3,340)
kWh
|
- |
$2,680
-
MMBtu
|
- | |
| 04 | 2.4221: Install compressor air intakes in coolest locations | $1,581 | $1,200 |
$1,560
18,449
kWh
|
$21
-
kW-mo/yr
|
- | - | |
| 05 | 3.3125: Use distillation, evaporation to remove contaminants | $63,847 | $26,000 | - | - | - |
$63,847
-
gal
|
|
| TOTAL RECOMMENDED | $111,113 | $111,200 |
$1,350
15,109
kWh
|
$21
-
kW-mo/yr
|
$45,895
-
MMBtu
|
$63,847
-
gal
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs