Assessment Year | 2009 |
---|---|
Principal Product | Automotive Components |
NAICS | 336211: Motor Vehicle Body Manufacturing |
SIC | 3714: Motor Vehicle Parts and Accessories |
Sales Range | $10 M to 50M |
# of Employees | 60 |
Plant Area |
105,000
ft2
|
Annual Production | 60,000
pieces
|
Production Hrs. Annual | 2,496
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $89,461 | 1,171,200 |
kWh
|
$0.076 |
Electricity Demand | $21,512 | 2,596 |
kW-mo/yr
|
$8.29 |
Electricity Fees | $8,021 | - |
|
- |
Natural Gas | $22,997 | 2,628 |
MMBtu
|
$8.75 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $40,838 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $27,695 | $55,216 |
$21,114
276,355
kWh
|
$6,581
-
kW-mo/yr
|
- | |
02 | 2.7135: Install occupancy sensors | $2,782 | $2,025 |
$2,067
27,061
kWh
|
$715
-
kW-mo/yr
|
- | |
03 | 2.2437: Recover waste heat from equipment | $3,526 | $1,000 | - | - |
$3,526
-
MMBtu
|
|
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $327 | - |
$246
3,226
kWh
|
$81
-
kW-mo/yr
|
- | |
05 | 2.4221: Install compressor air intakes in coolest locations | $118 | $500 |
$90
1,172
kWh
|
$28
-
kW-mo/yr
|
- | |
06 | 2.4133: Use most efficient type of electric motors | $193 | $300 |
$145
1,903
kWh
|
$48
-
kW-mo/yr
|
- | |
07 | 2.7231: Use radiant heater for spot heating | $4,732 | $8,000 | - | - |
$4,732
-
MMBtu
|
|
08 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $1,047 | $800 | - | - |
$1,047
-
MMBtu
|
|
09 | 4.454: Modify startup/shutdown times | $418 | - | - |
$418
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $40,838 | $67,841 |
$23,662
309,717
kWh
|
$7,871
-
kW-mo/yr
|
$9,305
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs