Assessment Year | 2009 |
---|---|
Principal Product | Printed Paper Products |
NAICS | 323117: Books Printing |
SIC | 2732: Book Printing |
Sales Range | $10 M to 50M |
# of Employees | 319 |
Plant Area |
300,000
ft2
|
Annual Production | 100,191,000
pieces
|
Production Hrs. Annual | 7,488
hrs
|
Location (State) | Iowa |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $496,054 | 13,252,124 |
kWh
|
$0.037 |
Electricity Demand | $297,238 | 26,133 |
kW-mo/yr
|
$11.37 |
Natural Gas | $257,657 | 25,769 |
MMBtu
|
$10.00 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $69,613 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $32,905 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Primary Raw Material Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7135: Install occupancy sensors | $1,093 | $2,775 |
$743
19,870
kWh
|
$350
-
kW-mo/yr
|
- | - | - | |
02 | 2.7111: Reduce illumination to minimum necessary levels | $4,724 | - |
$1,820
48,657
kWh
|
$2,553
-
kW-mo/yr
|
- | - | $351 | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,411 | - |
$375
10,025
kWh
|
$1,036
-
kW-mo/yr
|
- | - | - | |
04 | 2.4221: Install compressor air intakes in coolest locations | $1,086 | $2,000 |
$587
15,691
kWh
|
$499
-
kW-mo/yr
|
- | - | - | |
05 | 2.4133: Use most efficient type of electric motors | $31,812 | $45,980 |
$21,256
568,331
kWh
|
$10,556
-
kW-mo/yr
|
- | - | - | |
06 | 2.7231: Use radiant heater for spot heating | $3,152 | $2,750 | - | - | - |
$3,152
-
MMBtu
|
- | |
07 | 4.454: Modify startup/shutdown times | $26,335 | $18,750 | - | - | $26,335 | - | - | |
TOTAL RECOMMENDED | $69,613 | $72,255 |
$24,781
662,574
kWh
|
$14,994
-
kW-mo/yr
|
$26,335 |
$3,152
-
MMBtu
|
$351 | ||
TOTAL IMPLEMENTED | $32,905 | $48,755 |
$21,999
588,201
kWh
|
$10,906
-
kW-mo/yr
|
- | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Primary Raw Material Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs