Assessment Year 2008
Principal Product plastic containers
NAICS 326160: Plastics Bottle Manufacturing
SIC 3085: Plastics Bottles
Sales Range $10
M
to 50
M
# of Employees 300
Plant Area 877,000
ft2
Annual Production 295,699,564
pieces
Production Hrs. Annual 8,760
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $2,346,074 46,883,372
kWh
Electricity Demand $131,850 168,449
kW-mo/yr
Electricity Fees $170,842 -
Natural Gas $80,664 9,284
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $103,057 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Ancillary Material Cost Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $53,385 $253,134 $51,883
1,037,661
kWh
$1,502
-
kW-mo/yr
- - -
02 2.7135: Install occupancy sensors $374 $600 $309
6,179
kWh
$65
-
kW-mo/yr
- - -
03 2.7142: Utilize higher efficiency lamps and/or ballasts $699 $700 $433
8,655
kWh
$8
-
kW-mo/yr
- - $258
04 2.4221: Install compressor air intakes in coolest locations $18,734 $6,000 $18,376
367,526
kWh
$358
-
kW-mo/yr
- - -
05 2.4133: Use most efficient type of electric motors $15,592 $20,350 $15,294
305,889
kWh
$298
-
kW-mo/yr
- - -
06 2.7231: Use radiant heater for spot heating $2,435 $3,180 - - - $2,435
-
MMBtu
-
07 4.454: Modify startup/shutdown times $11,838 $18,000 - - $11,838 - -
TOTAL RECOMMENDED $103,057 $301,964 $86,295
1,725,910
kWh
$2,231
-
kW-mo/yr
$11,838 $2,435
-
MMBtu
$258
TOTAL IMPLEMENTED - - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs