Assessment Year | 2007 |
---|---|
Principal Product | Printing Products |
NAICS | 323111: Commercial Printing (except Screen and Books) |
SIC | 2752: Commercial Printing, Lithographic |
Sales Range | $10 M to 50M |
# of Employees | 95 |
Plant Area |
96,000
ft2
|
Annual Production | 500
units
|
Production Hrs. Annual | 5,840
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $212,776 | 1,020,000 |
kWh
|
$0.21 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $19,103 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $10,220 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4221: Install compressor air intakes in coolest locations | $641 | $300 |
$441
9,310
kWh
|
$200
-
kW-mo/yr
|
- | - | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,042 | - |
$717
15,129
kWh
|
$325
-
kW-mo/yr
|
- | - | |
03 | 2.4314: Use synthetic lubricant | $1,202 | $300 |
$827
17,456
kWh
|
$375
-
kW-mo/yr
|
- | - | |
04 | 2.7135: Install occupancy sensors | $3,724 | $225 |
$2,639
55,672
kWh
|
$1,085
-
kW-mo/yr
|
- | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $237 | $225 |
$141
2,330
kWh
|
$56
-
kW-mo/yr
|
- | $40 | |
06 | 2.4133: Use most efficient type of electric motors | $4,834 | $3,600 |
$3,654
77,078
kWh
|
$1,180
-
kW-mo/yr
|
- | - | |
07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,306 | $2,200 |
$2,499
52,723
kWh
|
$807
-
kW-mo/yr
|
- | - | |
08 | 4.632: Change operating conditions | $3,140 | - | - |
$3,140
-
kW-mo/yr
|
- | - | |
09 | 3.4151: Minimize water usage | $977 | $2,000 | - | - |
$977
-
Tgal
|
- | |
TOTAL RECOMMENDED | $19,103 | $8,850 |
$10,918
229,698
kWh
|
$7,168
-
kW-mo/yr
|
$977
-
Tgal
|
$40 | ||
TOTAL IMPLEMENTED | $10,220 | $6,625 |
$7,562
158,897
kWh
|
$2,618
-
kW-mo/yr
|
- | $40 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs