| Assessment Year | 2007 |
|---|---|
| Principal Product | Tractor cabs hoods and tanks |
| NAICS | 332999: All Other Miscellaneous Fabricated Metal Product Manufacturing |
| SIC | 3499: Fabricated Metal Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 281 |
| Plant Area |
175,000
ft2
|
| Annual Production | 117,750
units
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Illinois |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $429,615 | 7,256,516 |
kWh
|
$0.059 |
| Natural Gas | $427,998 | 49,102 |
MMBtu
|
$8.72 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $107,340 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.2437: Recover waste heat from equipment | $1,018 | $1,000 |
$1,018
287
kWh
|
- | - | - | |
| 02 | 2.4314: Use synthetic lubricant | $4,257 | $600 |
$2,814
100,534
kWh
|
$1,443
-
kW-mo/yr
|
- | - | |
| 03 | 2.4221: Install compressor air intakes in coolest locations | $2,520 | $600 |
$1,665
59,482
kWh
|
$855
-
kW-mo/yr
|
- | - | |
| 04 | 2.7495: Install replacement doors | $7,558 | $20,000 |
$1,966
286
kWh
|
- | - | $5,592 | |
| 05 | 2.1135: Repair furnaces and oven doors so that they seal efficiently | $15,124 | $6,800 | - | - |
$15,124
-
MMBtu
|
- | |
| 06 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $24,271 | $500 | - |
$24,271
-
kW-mo/yr
|
- | - | |
| 07 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $2,763 | - |
$2,763
75,712
kWh
|
- | - | - | |
| 08 | 2.7134: Use photocell controls | $36,411 | $10,000 |
$22,645
322,920
kWh
|
$13,604
-
kW-mo/yr
|
- | $162 | |
| 09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $10,900 | $9,230 |
$6,504
232,284
kWh
|
$4,078
-
kW-mo/yr
|
- | $318 | |
| 10 | 2.7135: Install occupancy sensors | $1,702 | $1,200 |
$1,009
27,636
kWh
|
$693
-
kW-mo/yr
|
- | - | |
| 11 | 2.7292: Lower ceiling to reduce conditioned space | $816 | $1,460 |
$816
216
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $107,340 | $51,390 |
$41,200
819,357
kWh
|
$44,944
-
kW-mo/yr
|
$15,124
-
MMBtu
|
$6,072 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs