Assessment Year | 2006 |
---|---|
Principal Product | Shade Structures |
NAICS | 332311: Prefabricated Metal Building and Component Manufacturing |
SIC | 3444: Sheet Metal Work |
Sales Range | $5 M to 10M |
# of Employees | 68 |
Plant Area |
133,000
ft2
|
Annual Production | 80,000
pieces
|
Production Hrs. Annual | 3,120
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $88,485 | 1,769,700 |
kWh
|
$0.050 |
Electricity Demand | $55,152 | 9,192 |
kW-mo/yr
|
$6.00 |
Natural Gas | $46,962 | 52,991 |
MMBtu
|
$0.89 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $25,579 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $491 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.6242: Minimize operation of equipment maintained in standby condition | $9,543 | - |
$9,543
190,857
kWh
|
- | - | |
02 | 2.4314: Use synthetic lubricant | $1,020 | $1,500 |
$698
13,965
kWh
|
$322
-
kW-mo/yr
|
- | |
03 | 2.4221: Install compressor air intakes in coolest locations | $491 | $1,250 |
$336
6,726
kWh
|
$155
-
kW-mo/yr
|
- | |
04 | 2.7231: Use radiant heater for spot heating | $7,677 | $9,600 | - | - |
$7,677
-
MMBtu
|
|
05 | 2.1221: Replace obsolete burners with more efficient ones | $1,824 | $1,200 | - | - |
$1,824
-
MMBtu
|
|
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,382 | $4,955 |
$2,094
41,897
kWh
|
$1,288
-
kW-mo/yr
|
- | |
07 | 2.7135: Install occupancy sensors | $1,221 | $525 |
$791
15,818
kWh
|
$430
-
kW-mo/yr
|
- | |
08 | 2.4133: Use most efficient type of electric motors | $421 | $1,230 |
$238
4,756
kWh
|
$183
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $25,579 | $20,260 |
$13,700
274,019
kWh
|
$2,378
-
kW-mo/yr
|
$9,501
-
MMBtu
|
||
TOTAL IMPLEMENTED | $491 | $1,250 |
$336
6,726
kWh
|
$155
-
kW-mo/yr
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs