Assessment Year 2002
Principal Product Hydraulic Hose Assemblies
NAICS
n/a
SIC 3492: Fluid Power Valves and Hose Fittings
Sales Range $10
M
to 50
M
# of Employees 125
Plant Area 30,000
ft2
Annual Production 2,789,578
pieces
Production Hrs. Annual 8,760
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $46,461 949,920
kWh
Electricity Demand $14,140 1,640
kW-mo/yr
Electricity Fees $2,162 -
Natural Gas $10,673 2,475
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $8,215 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $3,218

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings One-time Revenue or Avoided Cost Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $2,416 $9,030 $1,311
22,732
kWh
$108
-
kW-mo/yr
- $997
02 2.7135: Install occupancy sensors $2,151 $825 $1,965
34,053
kWh
$186
-
kW-mo/yr
- -
03 2.7231: Use radiant heater for spot heating $1,288 $4,000 - - $1,288
-
MMBtu
-
04 2.4231: Reduce the pressure of compressed air to the minimum required $769 - $660
11,444
kWh
$109
-
kW-mo/yr
- -
05 2.1123: Install automatic stack damper $608 $2,000 - - $608
-
MMBtu
-
06 2.7494: Install storm windows and doors $374 $1,000 - - $374
-
MMBtu
-
07 2.7142: Utilize higher efficiency lamps and/or ballasts $311 $280 $173
2,996
kWh
$14
-
kW-mo/yr
- $124
08 2.4221: Install compressor air intakes in coolest locations $298 $400 $256
4,437
kWh
$42
-
kW-mo/yr
- -
TOTAL RECOMMENDED $8,215 $17,535 $4,365
75,662
kWh
$459
-
kW-mo/yr
$2,270
-
MMBtu
$1,121
TOTAL IMPLEMENTED $3,218 $1,225 $2,881
49,934
kWh
$337
-
kW-mo/yr
- -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs