Assessment Year | 1999 |
---|---|
Principal Product | Molded Plastic Gears |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 34 |
Plant Area |
17,761
ft2
|
Annual Production | 80,000,000
pieces
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $81,423 | 2,030,774 |
kWh
|
$0.040 |
Electricity Demand | $52,644 | 4,296 |
kW-mo/yr
|
$12.25 |
Electricity Fees | $578 | - |
|
- |
Natural Gas | $3,882 | 744 |
MMBtu
|
$5.22 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $40,228 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $17,892 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4221: Install compressor air intakes in coolest locations | $1,753 | $800 |
$1,218
31,946
kWh
|
$535
-
kW-mo/yr
|
- | - | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,108 | - |
$770
20,223
kWh
|
$338
-
kW-mo/yr
|
- | - | |
03 | 2.7135: Install occupancy sensors | $876 | $525 |
$552
14,361
kWh
|
$324
-
kW-mo/yr
|
- | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $308 | $566 |
$142
3,810
kWh
|
$166
-
kW-mo/yr
|
- | - | |
05 | 2.2523: Reduce infiltration to refrigerated areas; isolate hot equipment from refrigerated areas | $291 | $500 |
$202
5,275
kWh
|
$89
-
kW-mo/yr
|
- | - | |
06 | 3.5212: Regrind, reuse, or sell scrap plastic parts | $20,292 | $1,500 | - | - |
$20,292
-
lb
|
- | |
07 | 4.441: Install automatic packing equipment | $15,600 | $61,950 | - | - | - | $15,600 | |
TOTAL RECOMMENDED | $40,228 | $65,841 |
$2,884
75,615
kWh
|
$1,452
-
kW-mo/yr
|
$20,292
-
lb
|
$15,600 | ||
TOTAL IMPLEMENTED | $17,892 | $63,041 |
$1,464
38,394
kWh
|
$828
-
kW-mo/yr
|
- | $15,600 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs