Assessment Year 1998
Principal Product Vinyl Windows and Sliding Glass Doors
NAICS
n/a
SIC 3089: Plastics Products, Not Elsewhere Classified
Sales Range $5
M
to 10
M
# of Employees 78
Plant Area 78,000
ft2
Annual Production 60,000
pieces
Production Hrs. Annual 5,200
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $25,817 589,977
kWh
Electricity Demand $22,702 1,896
kW-mo/yr
Electricity Fees $509 -
Natural Gas $10,260 1,855
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $13,438 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $13,438

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Water Disposal Savings Personnel Changes Savings Administrative Changes Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $637 $945 $366
9,965
kWh
$271
-
kW-mo/yr
- - -
02 2.4221: Install compressor air intakes in coolest locations $395 $600 $338
9,086
kWh
$57
-
kW-mo/yr
- - -
03 2.4231: Reduce the pressure of compressed air to the minimum required $305 $100 $305
8,206
kWh
- - - -
04 2.4314: Use synthetic lubricant $191 $150 $134
3,517
kWh
$57
-
kW-mo/yr
- - -
05 3.5313: Increase amount of waste recovered for resale $4,287 $1,525 - - - - $4,287
06 3.5313: Increase amount of waste recovered for resale $3,425 $400 - - - - $3,425
07 3.4151: Minimize water usage $823 $1,125 - - $823
-
Tgal
- -
08 4.652: Replace existing equipment with more suitable substitutes $3,375 $4,395 $(-312.0)
(-8,499)
kWh
$(-213.0)
-
kW-mo/yr
- $3,900 -
TOTAL RECOMMENDED $13,438 $9,240 $831
22,275
kWh
$172
-
kW-mo/yr
$823
-
Tgal
$3,900 $7,712
TOTAL IMPLEMENTED $13,438 $9,240 $831
22,275
kWh
$172
-
kW-mo/yr
$823
-
Tgal
$3,900 $7,712
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Water Disposal Savings Personnel Changes Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs