| Assessment Year | 1996 |
|---|---|
| Principal Product | Truck Bodies |
| NAICS |
n/a
|
| SIC | 3713: Truck and Bus Bodies |
| Sales Range | $5 M to 10M |
| # of Employees | 43 |
| Plant Area |
48,500
ft2
|
| Annual Production | 1,300
pieces
|
| Production Hrs. Annual | 2,340
hrs
|
| Location (State) | Illinois |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $15,532 | 344,080 |
kWh
|
$0.045 |
| Electricity Demand | $20,218 | 1,662 |
kW-mo/yr
|
$12.16 |
| Electricity Fees | $374 | - |
|
- |
| Natural Gas | $13,614 | 3,722 |
MMBtu
|
$3.66 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $20,251 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $2,206 | $3,779 | n/a | - | - |
$2,206
-
MMBtu
|
- |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,491 | $850 | n/a |
$1,491
33,118
kWh
|
- | - | - |
| 03 | 2.7135: Install occupancy sensors | $643 | $600 | n/a |
$302
6,741
kWh
|
$341
-
kW-mo/yr
|
- | - |
| 04 | 2.4133: Use most efficient type of electric motors | $527 | $1,410 | n/a | - |
$527
-
kW-mo/yr
|
- | - |
| 05 | 2.4221: Install compressor air intakes in coolest locations | $498 | $500 | n/a |
$218
4,982
kWh
|
$280
-
kW-mo/yr
|
- | - |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $216 | $337 | n/a |
$92
2,052
kWh
|
$124
-
kW-mo/yr
|
- | - |
| 07 | 3.2123: Convert to high volume low pressure (hvlp) paint guns | $14,670 | $2,700 | n/a | - | - | - | $14,670 |
| TOTAL RECOMMENDED | $20,251 | $10,176 |
$2,103
46,893
kWh
|
$1,272
-
kW-mo/yr
|
$2,206
-
MMBtu
|
$14,670 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs