| Assessment Year | 1996 |
|---|---|
| Principal Product | Tube Assembly and Machined Parts |
| NAICS |
n/a
|
| SIC | 3443: Fabricated Plate Work (Boiler Shops) |
| Sales Range | $10 M to 50M |
| # of Employees | 150 |
| Plant Area |
90,000
ft2
|
| Annual Production | 2,000
ton
|
| Production Hrs. Annual | 5,200
hrs
|
| Location (State) | Illinois |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $108,948 | 2,064,478 |
kWh
|
$0.053 |
| Electricity Demand | $13,677 | 5,762 |
kW-mo/yr
|
$2.37 |
| Electricity Fees | $654 | - |
|
- |
| Natural Gas | $19,807 | 4,639 |
MMBtu
|
$4.27 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $24,854 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Consumption Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $5,364 | $14,830 |
$4,818
132,474
kWh
|
$546
-
kW-mo/yr
|
- | - | |
| 02 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $5,243 | $7,000 |
$7,966
218,933
kWh
|
$1,197
-
kW-mo/yr
|
$(-3,920.0)
-
MMBtu
|
- | |
| 03 | 2.2437: Recover waste heat from equipment | $3,099 | $1,500 | - | - |
$3,099
-
MMBtu
|
- | |
| 04 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $2,753 | $3,689 | - | - |
$2,753
-
MMBtu
|
- | |
| 05 | 2.7135: Install occupancy sensors | $1,610 | $975 |
$1,421
38,980
kWh
|
$189
-
kW-mo/yr
|
- | - | |
| 06 | 2.4221: Install compressor air intakes in coolest locations | $506 | $500 |
$444
12,309
kWh
|
$62
-
kW-mo/yr
|
- | - | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $459 | $1,178 |
$386
7,620
kWh
|
$73
-
kW-mo/yr
|
- | - | |
| 08 | 3.4115: Recover and reuse cooling water | $5,820 | $4,500 |
$(-700.0)
(-19,343)
kWh
|
- | - |
$6,520
-
Tgal
|
|
| TOTAL RECOMMENDED | $24,854 | $34,172 |
$14,335
390,973
kWh
|
$2,067
-
kW-mo/yr
|
$1,932
-
MMBtu
|
$6,520
-
Tgal
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Consumption Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs