| Assessment Year | 1996 |
|---|---|
| Principal Product | Forged Steel |
| NAICS |
n/a
|
| SIC | 3462: Iron and Steel Forgings |
| Sales Range | $50 M to 100M |
| # of Employees | 100 |
| Plant Area |
122,000
ft2
|
| Annual Production | 4,400
ton
|
| Production Hrs. Annual | 2,080
hrs
|
| Location (State) | Illinois |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $64,700 | 2,517,585 |
kWh
|
$0.026 |
| Electricity Demand | $56,538 | 8,818 |
kW-mo/yr
|
$6.41 |
| Electricity Fees | $12,427 | - |
|
- |
| Natural Gas | $356,195 | 136,617 |
MMBtu
|
$2.61 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $35,267 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7231: Use radiant heater for spot heating | $8,237 | $7,500 | - | - |
$8,237
-
MMBtu
|
- | - | - | - | |
| 02 | 2.4133: Use most efficient type of electric motors | $4,102 | $19,430 |
$1,971
76,788
kWh
|
$2,131
-
kW-mo/yr
|
- | - | - | - | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,518 | $5,540 |
$1,573
61,254
kWh
|
$1,561
-
kW-mo/yr
|
- | - | - | $88 | $296 | |
| 04 | 2.4221: Install compressor air intakes in coolest locations | $1,602 | $600 |
$647
25,205
kWh
|
$955
-
kW-mo/yr
|
- | - | - | - | - | |
| 05 | 2.7135: Install occupancy sensors | $771 | $600 |
$404
15,826
kWh
|
$367
-
kW-mo/yr
|
- | - | - | - | - | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $634 | $1,527 |
$299
11,723
kWh
|
$335
-
kW-mo/yr
|
- | - | - | - | - | |
| 07 | 3.5217: Reuse / recycle/ sell paper products | $8,635 | $7,000 | - | - | - | - |
$3,000
-
lb
|
$(-935.0) | $6,570 | |
| 08 | 3.4115: Recover and reuse cooling water | $7,768 | $18,570 |
$(-300.0)
(-11,723)
kWh
|
$(-323.0)
-
kW-mo/yr
|
- |
$8,391
-
Tgal
|
- | - | - | |
| TOTAL RECOMMENDED | $35,267 | $60,767 |
$4,594
179,073
kWh
|
$5,026
-
kW-mo/yr
|
$8,237
-
MMBtu
|
$8,391
-
Tgal
|
$3,000
-
lb
|
$(-847.0) | $6,866 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs