ITAC Assessment: BD0060
ITAC logo
ITAC Assessment: BD0060
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1996
Principal Product Sewer Cleaners
NAICS
n/a
SIC 3589: Service Industry Machinery, Not Elsewhere Classified
Sales Range $50
M
to 100
M
# of Employees 300
Plant Area 240,000
ft2
Annual Production 342
pieces
Production Hrs. Annual 7,488
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $120,749 3,031,653
kWh
Electricity Demand $87,817 7,199
kW-mo/yr
Electricity Fees $13,621 -
Natural Gas $79,526 24,549
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $222,486 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $210,717

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Water Disposal Savings Other Liquid (haz) Savings Personnel Changes Savings Ancillary Material Cost Savings Water Consumption Savings
01 2.7135: Install occupancy sensors $9,949 $3,500 $6,653
167,057
kWh
$3,296
-
kW-mo/yr
- - - - -
02 2.7142: Utilize higher efficiency lamps and/or ballasts $5,990 $17,287 $2,990
75,029
kWh
$3,000
-
kW-mo/yr
- - - - -
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,318 $1,200 $3,318
83,236
kWh
- - - - - -
04 2.4133: Use most efficient type of electric motors $1,948 $3,740 $1,424
35,756
kWh
$524
-
kW-mo/yr
- - - - -
05 2.4221: Install compressor air intakes in coolest locations $1,874 $750 $1,874
47,186
kWh
- - - - - -
06 3.2123: Convert to high volume low pressure (hvlp) paint guns $171,645 $4,370 - - - - - $171,645 -
07 3.3125: Use distillation, evaporation to remove contaminants $23,857 $18,500 $(-369.0)
(-9,379)
kWh
- - $10,786
-
gal
$(-5,018.0) $18,458 -
08 3.5311: Recover and reuse waste material $3,905 $1,000 $(-32.0)
(-2,345)
kWh
$(-99.0)
-
kW-mo/yr
$2,831
-
Tgal
- - - $1,205
-
Tgal
TOTAL RECOMMENDED $222,486 $50,347 $15,858
396,540
kWh
$6,721
-
kW-mo/yr
$2,831
-
Tgal
$10,786
-
gal
$(-5,018.0) $190,103 $1,205
-
Tgal
TOTAL IMPLEMENTED $210,717 $31,310 $11,026
276,670
kWh
$3,820
-
kW-mo/yr
- $10,786
-
gal
$(-5,018.0) $190,103 -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Water Disposal Savings Other Liquid (haz) Savings Personnel Changes Savings Ancillary Material Cost Savings Water Consumption Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs