Assessment Year | 1996 |
---|---|
Principal Product | Electric Generator Housings |
NAICS |
n/a
|
SIC | 3469: Metal Stampings, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 100 |
Plant Area |
40,000
ft2
|
Annual Production | 650
pieces
|
Production Hrs. Annual | 6,656
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $43,429 | 924,678 |
kWh
|
$0.047 |
Electricity Demand | $4,769 | 2,024 |
kW-mo/yr
|
$2.36 |
Electricity Fees | $2,790 | - |
|
- |
Natural Gas | $33,968 | 8,642 |
MMBtu
|
$3.93 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $8,994 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $7,631 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $5,160 | $5,420 | - | - |
$5,160
-
MMBtu
|
- | - | |
02 | 2.7135: Install occupancy sensors | $1,983 | $1,275 |
$1,773
51,876
kWh
|
$210
-
kW-mo/yr
|
- | - | - | |
03 | 2.4133: Use most efficient type of electric motors | $877 | $2,010 |
$802
23,447
kWh
|
$75
-
kW-mo/yr
|
- | - | - | |
04 | 2.4221: Install compressor air intakes in coolest locations | $488 | $300 |
$488
14,361
kWh
|
- | - | - | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $427 | $835 |
$363
7,620
kWh
|
$64
-
kW-mo/yr
|
- | - | - | |
06 | 3.2123: Convert to high volume low pressure (hvlp) paint guns | - | $3,550 | - | - | - | - | - | |
07 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $59 | $7,788 |
$(-100.0)
(-2,931)
kWh
|
- | - |
$456
-
lb
|
$(-297.0) | |
TOTAL RECOMMENDED | $8,994 | $21,178 |
$3,326
94,373
kWh
|
$349
-
kW-mo/yr
|
$5,160
-
MMBtu
|
$456
-
lb
|
$(-297.0) | ||
TOTAL IMPLEMENTED | $7,631 | $6,995 |
$2,261
66,237
kWh
|
$210
-
kW-mo/yr
|
$5,160
-
MMBtu
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs