| Assessment Year | 1996 |
|---|---|
| Principal Product | Garage Door Openers |
| NAICS |
n/a
|
| SIC | 3442: Metal Doors, Sash, Frames, Molding, and Trim Manufacturing |
| Sales Range | $5 M to 10M |
| # of Employees | 146 |
| Plant Area |
118,000
ft2
|
| Annual Production | 48,000
pieces
|
| Production Hrs. Annual | 2,340
hrs
|
| Location (State) | Illinois |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $33,891 | 937,573 |
kWh
|
$0.036 |
| Electricity Demand | $42,746 | 3,476 |
kW-mo/yr
|
$12.30 |
| Electricity Fees | $5,811 | - |
|
- |
| Natural Gas | $25,460 | 10,030 |
MMBtu
|
$2.54 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $17,087 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,794 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings | Water Consumption Savings |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,693 | $8,316 |
$1,243
38,980
kWh
|
$2,450
-
kW-mo/yr
|
- | - | - | - | - | |
| 02 | 2.4226: Use / purchase optimum sized compressor | $3,441 | $8,447 |
$406
12,603
kWh
|
$1,064
-
kW-mo/yr
|
- | $1,674 | - | - |
$297
-
Tgal
|
|
| 03 | 2.4133: Use most efficient type of electric motors | $1,101 | $4,220 |
$443
13,775
kWh
|
$658
-
kW-mo/yr
|
- | - | - | - | - | |
| 04 | 2.7135: Install occupancy sensors | $487 | $675 |
$168
5,275
kWh
|
$319
-
kW-mo/yr
|
- | - | - | - | - | |
| 05 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $7,212 | $500 | - | - |
$2,340
-
lb
|
$(-1,000.0) | - | $5,872 | - | |
| 06 | 3.2123: Convert to high volume low pressure (hvlp) paint guns | $1,153 | $650 | - | - | - | - | $(-300.0) | $1,453 | - | |
| TOTAL RECOMMENDED | $17,087 | $22,808 |
$2,260
70,633
kWh
|
$4,491
-
kW-mo/yr
|
$2,340
-
lb
|
$674 | $(-300.0) | $7,325 |
$297
-
Tgal
|
||
| TOTAL IMPLEMENTED | $4,794 | $12,536 |
$1,686
52,755
kWh
|
$3,108
-
kW-mo/yr
|
- | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings | Water Consumption Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs