| Assessment Year | 1995 |
|---|---|
| Principal Product | Hourmeters, Heavy duty flashers, Pressure switches, Shifter |
| NAICS |
n/a
|
| SIC | 3694: Electrical Equipment for Internal Combustion Engines |
| Sales Range | $10 M to 50M |
| # of Employees | 175 |
| Plant Area |
73,358
ft2
|
| Annual Production | 9,000,000
pieces
|
| Production Hrs. Annual | 4,420
hrs
|
| Location (State) | Illinois |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $196,486 | 3,301,876 |
kWh
|
$0.060 |
| Natural Gas | $15,932 | 3,939 |
MMBtu
|
$4.04 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $13,713 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $7,820 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4221: Install compressor air intakes in coolest locations | $382 | $750 |
$382
6,448
kWh
|
- | |
| 02 | 2.2437: Recover waste heat from equipment | $3,916 | $3,500 | - |
$3,916
-
MMBtu
|
|
| 03 | 2.4133: Use most efficient type of electric motors | $3,605 | $8,310 |
$3,605
60,668
kWh
|
- | |
| 04 | 2.1113: Reduce combustion air flow to optimum | $2,288 | $3,000 | - |
$2,288
-
MMBtu
|
|
| 05 | 2.7135: Install occupancy sensors | $2,726 | $975 |
$2,726
45,721
kWh
|
- | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $494 | $450 |
$494
8,206
kWh
|
- | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $302 | $684 |
$302
4,982
kWh
|
- | |
| TOTAL RECOMMENDED | $13,713 | $17,669 |
$7,509
126,025
kWh
|
$6,204
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $7,820 | $6,359 |
$3,904
65,357
kWh
|
$3,916
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs