Assessment Year | 1995 |
---|---|
Principal Product | Hourmeters, Heavy duty flashers, Pressure switches, Shifter |
NAICS |
n/a
|
SIC | 3694: Electrical Equipment for Internal Combustion Engines |
Sales Range | $10 M to 50M |
# of Employees | 175 |
Plant Area |
73,358
ft2
|
Annual Production | 9,000,000
pieces
|
Production Hrs. Annual | 4,420
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $196,486 | 3,301,876 |
kWh
|
$0.060 |
Natural Gas | $15,932 | 3,939 |
MMBtu
|
$4.04 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $13,713 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $7,820 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4221: Install compressor air intakes in coolest locations | $382 | $750 |
$382
6,448
kWh
|
- | |
02 | 2.2437: Recover waste heat from equipment | $3,916 | $3,500 | - |
$3,916
-
MMBtu
|
|
03 | 2.4133: Use most efficient type of electric motors | $3,605 | $8,310 |
$3,605
60,668
kWh
|
- | |
04 | 2.1113: Reduce combustion air flow to optimum | $2,288 | $3,000 | - |
$2,288
-
MMBtu
|
|
05 | 2.7135: Install occupancy sensors | $2,726 | $975 |
$2,726
45,721
kWh
|
- | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $494 | $450 |
$494
8,206
kWh
|
- | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $302 | $684 |
$302
4,982
kWh
|
- | |
TOTAL RECOMMENDED | $13,713 | $17,669 |
$7,509
126,025
kWh
|
$6,204
-
MMBtu
|
||
TOTAL IMPLEMENTED | $7,820 | $6,359 |
$3,904
65,357
kWh
|
$3,916
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs