| Assessment Year | 1995 |
|---|---|
| Principal Product | Cold Run Steel Bars |
| NAICS |
n/a
|
| SIC | 3316: Cold-Rolled Steel Sheet, Strip, and Bars |
| Sales Range | $10 M to 50M |
| # of Employees | 30 |
| Plant Area |
49,000
ft2
|
| Annual Production | 32,000
ton
|
| Production Hrs. Annual | 5,200
hrs
|
| Location (State) | Illinois |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $161,057 | 2,229,191 |
kWh
|
$0.072 |
| Natural Gas | $26,194 | 8,292 |
MMBtu
|
$3.16 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $18,992 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $2,935 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4221: Install compressor air intakes in coolest locations | $800 | $950 |
$800
11,137
kWh
|
- | |
| 02 | 2.2437: Recover waste heat from equipment | $1,940 | $1,500 | - |
$1,940
-
MMBtu
|
|
| 03 | 2.4133: Use most efficient type of electric motors | $10,813 | $32,290 |
$10,813
149,766
kWh
|
- | |
| 04 | 2.7135: Install occupancy sensors | $1,772 | $525 |
$1,772
24,619
kWh
|
- | |
| 05 | 2.7111: Reduce illumination to minimum necessary levels | $3,472 | $400 |
$3,472
48,066
kWh
|
- | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $195 | $170 |
$195
2,638
kWh
|
- | |
| TOTAL RECOMMENDED | $18,992 | $35,835 |
$17,052
236,226
kWh
|
$1,940
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $2,935 | $2,620 |
$995
13,775
kWh
|
$1,940
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs