Assessment Year | 1995 |
---|---|
Principal Product | Commercial Printing |
NAICS |
n/a
|
SIC | 2732: Book Printing |
Sales Range | $50 M to 100M |
# of Employees | 220 |
Plant Area |
160,000
ft2
|
Annual Production | 589,000,000
pieces
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $992,704 | 15,787,222 |
kWh
|
$0.063 |
Natural Gas | $210,899 | 85,810 |
MMBtu
|
$2.46 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $94,662 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $77,756 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $26,238 | $54,640 |
$26,238
417,351
kWh
|
- | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $23,437 | $12,950 |
$23,437
372,802
kWh
|
- | |
03 | 2.7111: Reduce illumination to minimum necessary levels | $11,970 | $1,575 |
$11,970
190,504
kWh
|
- | |
04 | 2.7447: Install vinyl strip / high speed / air curtain doors | $4,847 | $5,000 | - |
$4,847
-
MMBtu
|
|
05 | 2.7135: Install occupancy sensors | $5,009 | $825 |
$5,009
81,184
kWh
|
- | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $11,102 | $6,784 |
$11,102
176,436
kWh
|
- | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $12,059 | $2,250 |
$12,059
191,676
kWh
|
- | |
TOTAL RECOMMENDED | $94,662 | $84,024 |
$89,815
1,429,953
kWh
|
$4,847
-
MMBtu
|
||
TOTAL IMPLEMENTED | $77,756 | $76,774 |
$77,756
1,238,277
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs