| Assessment Year | 1995 |
|---|---|
| Principal Product | Corrugated Containers |
| NAICS |
n/a
|
| SIC | 2653: Corrugated and Solid Fiber Boxes |
| Sales Range | $5 M to 10M |
| # of Employees | 48 |
| Plant Area |
63,000
ft2
|
| Annual Production | 75,000
thousand feet
|
| Production Hrs. Annual | 2,210
hrs
|
| Location (State) | Illinois |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $61,757 | 296,307 |
kWh
|
$0.21 |
| Natural Gas | $8,918 | 4,343 |
MMBtu
|
$2.05 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $7,656 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $1,747 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $3,044 | $3,180 |
$3,044
14,654
kWh
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,240 | $730 |
$1,240
5,862
kWh
|
|
| 03 | 2.7111: Reduce illumination to minimum necessary levels | $507 | $20 |
$507
2,345
kWh
|
|
| 04 | 2.4221: Install compressor air intakes in coolest locations | $212 | $200 |
$212
1,172
kWh
|
|
| 05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,388 | $60 |
$2,388
11,430
kWh
|
|
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $265 | $95 |
$265
1,172
kWh
|
|
| TOTAL RECOMMENDED | $7,656 | $4,285 |
$7,656
36,635
kWh
|
||
| TOTAL IMPLEMENTED | $1,747 | $750 |
$1,747
8,207
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs