| Assessment Year | 1995 |
|---|---|
| Principal Product | Custom Machinery |
| NAICS |
n/a
|
| SIC | 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified |
| Sales Range | $5 M to 10M |
| # of Employees | 80 |
| Plant Area |
85,000
ft2
|
| Annual Production | 25
ton
|
| Production Hrs. Annual | 5,460
hrs
|
| Location (State) | Illinois |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $132,773 | 2,147,128 |
kWh
|
$0.062 |
| Natural Gas | $15,139 | 3,221 |
MMBtu
|
$4.70 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $8,777 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $2,822 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,980 | $500 |
$1,980
31,946
kWh
|
- | |
| 02 | 2.7111: Reduce illumination to minimum necessary levels | $807 | $600 |
$807
13,189
kWh
|
- | |
| 03 | 2.7135: Install occupancy sensors | $1,215 | $150 |
$1,215
19,637
kWh
|
- | |
| 04 | 2.4221: Install compressor air intakes in coolest locations | $801 | $20 |
$801
12,896
kWh
|
- | |
| 05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $534 | $6,380 |
$534
8,792
kWh
|
- | |
| 06 | 2.4133: Use most efficient type of electric motors | $3,132 | $64 |
$3,132
50,703
kWh
|
- | |
| 07 | 2.6214: Shut off pilots in standby equipment | $308 | - | - |
$308
-
MMBtu
|
|
| TOTAL RECOMMENDED | $8,777 | $7,714 |
$8,469
137,163
kWh
|
$308
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $2,822 | $6,880 |
$2,514
40,738
kWh
|
$308
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs