Assessment Year | 1995 |
---|---|
Principal Product | Sheet Metal Products |
NAICS |
n/a
|
SIC | 3444: Sheet Metal Work |
Sales Range | $10 M to 50M |
# of Employees | 465 |
Plant Area |
219,760
ft2
|
Annual Production | 22,000,000
lb
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $312,414 | 6,029,895 |
kWh
|
$0.052 |
Natural Gas | $136,807 | 34,677 |
MMBtu
|
$3.95 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $45,238 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $30,091 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $30,091 | $52,250 |
$30,091
-
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,313 | $10,254 |
$5,313
102,579
kWh
|
- | |
03 | 2.7447: Install vinyl strip / high speed / air curtain doors | $6,172 | $7,470 | - |
$6,172
-
MMBtu
|
|
04 | 2.4133: Use most efficient type of electric motors | $3,662 | $9,150 |
$3,662
70,633
kWh
|
- | |
TOTAL RECOMMENDED | $45,238 | $79,124 |
$39,066
173,212
kWh
|
$6,172
-
MMBtu
|
||
TOTAL IMPLEMENTED | $30,091 | $52,250 |
$30,091
-
kWh
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs