Assessment Year | 1995 |
---|---|
Principal Product | Railroad Cars |
NAICS |
n/a
|
SIC | 3743: Railroad Equipment |
Sales Range | $50 M to 100M |
# of Employees | 235 |
Plant Area |
87,900
ft2
|
Annual Production | 1,250
pieces
|
Production Hrs. Annual | 4,000
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $421,842 | 5,234,467 |
kWh
|
$0.081 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $9,486 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $7,269 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $591 | $984 |
$591
7,327
kWh
|
|
02 | 2.7111: Reduce illumination to minimum necessary levels | $3,496 | $100 |
$3,496
43,376
kWh
|
|
03 | 2.4133: Use most efficient type of electric motors | $2,217 | $7,250 |
$2,217
27,550
kWh
|
|
04 | 2.4221: Install compressor air intakes in coolest locations | $3,182 | $1,500 |
$3,182
39,566
kWh
|
|
TOTAL RECOMMENDED | $9,486 | $9,834 |
$9,486
117,819
kWh
|
||
TOTAL IMPLEMENTED | $7,269 | $2,584 |
$7,269
90,269
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs