| Assessment Year | 1994 |
|---|---|
| Principal Product | Printed Labels |
| NAICS |
n/a
|
| SIC | 2671: Packaging Paper and Plastics Film, Coated and Laminated |
| Sales Range | $10 M to 50M |
| # of Employees | 390 |
| Plant Area |
295,000
ft2
|
| Annual Production | 6,000,000,000,000
pieces
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | Illinois |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $427,155 | 9,116,647 |
kWh
|
$0.047 |
| Natural Gas | $158,035 | 32,722 |
MMBtu
|
$4.83 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $32,037 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Water Consumption Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4221: Install compressor air intakes in coolest locations | $1,745 | $2,250 |
$1,745
37,222
kWh
|
- | - | |
| 02 | 2.2437: Recover waste heat from equipment | $7,926 | $100 | - |
$7,926
-
MMBtu
|
- | |
| 03 | 3.4115: Recover and reuse cooling water | $1,975 | $5,000 | - | - |
$1,975
-
Tgal
|
|
| 04 | 2.4133: Use most efficient type of electric motors | $7,553 | $13,640 |
$7,553
161,196
kWh
|
- | - | |
| 05 | 2.1222: Install turbulators | $1,003 | $2,400 | - |
$1,003
-
MMBtu
|
- | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $11,835 | $13,008 |
$11,835
252,638
kWh
|
- | - | |
| TOTAL RECOMMENDED | $32,037 | $36,398 |
$21,133
451,056
kWh
|
$8,929
-
MMBtu
|
$1,975
-
Tgal
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Water Consumption Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs