| Assessment Year | 1988 |
|---|---|
| Principal Product | WOOD DESKS & CABINETS |
| NAICS |
n/a
|
| SIC | 2521: Wood Office Furniture |
| Sales Range | $5 M to 10M |
| # of Employees | 300 |
| Plant Area |
n/a
|
| Annual Production | 50,000
pieces
|
| Production Hrs. Annual | 2,000
hrs
|
| Location (State) | North Carolina |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $305,672 | 5,000,879 |
kWh
|
$0.061 |
| Natural Gas | $1,960 | 345 |
MMBtu
|
$5.68 |
| Wood | $16,000 | 15,996 |
MMBtu
|
$1.00 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $24,441 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $13,431 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.3191: Use demand controller or load shedder | $8,515 | $2,000 |
$8,515
-
kWh
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $11,258 | $11,200 |
$11,258
184,349
kWh
|
|
| 03 | 2.4133: Use most efficient type of electric motors | $784 | $998 |
$784
12,896
kWh
|
|
| 04 | 2.4312: Improve lubrication practices | $526 | - |
$526
8,499
kWh
|
|
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $736 | - |
$736
12,016
kWh
|
|
| 06 | 2.4221: Install compressor air intakes in coolest locations | $653 | $600 |
$653
10,551
kWh
|
|
| 07 | 2.6218: Turn off equipment when not in use | $1,969 | - |
$1,969
32,239
kWh
|
|
| TOTAL RECOMMENDED | $24,441 | $14,798 |
$24,441
260,550
kWh
|
||
| TOTAL IMPLEMENTED | $13,431 | $12,798 |
$13,431
219,812
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||