| Assessment Year | 2023 |
|---|---|
| Principal Product | Water |
| NAICS | 221310: Water Supply and Irrigation Systems |
| SIC | 4941: Water Supply |
| Sales Range | $1 M to 5M |
| # of Employees | 2 |
| Plant Area |
16,723,737
ft2
|
| Annual Production | 220,000
Tgal
|
| Production Hrs. Annual | 5,840
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $17,781 | 409,680 |
kWh
|
$0.043 | |
| Electricity Demand | $15,908 | 1,385 |
kW-mo/yr
|
$11.49 | |
| Electricity Fees | $406 | - |
|
- | |
| Waste Disposal Costs | |||||
| Water Usage | $49,500 | 220,000 |
Tgal
|
$0.23 | |
| TOTAL YEARLY COSTS | $83,595 | ||||
| RECOMMENDED SAVINGS* | $2,026 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $1,357 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Primary Raw Material Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $337 | $921 |
$337
7,830
kWh
|
- | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $303 | $583 |
$303
7,054
kWh
|
- | - | |
| 03 | 2.7135: Install occupancy sensors | $251 | $195 |
$251
5,827
kWh
|
- | - | |
| 04 | 3.7311: Maintain machines to reduce leaks | $717 | $884 | - | $4 | $712 | |
| 05 | 2.7232: Replace existing hvac unit with high efficiency model | $419 | $4,300 |
$419
9,738
kWh
|
- | - | |
| TOTAL RECOMMENDED | $2,026 | $6,883 |
$1,309
30,450
kWh
|
$4 | $712 | ||
| TOTAL IMPLEMENTED | $1,357 | $2,388 |
$640
14,884
kWh
|
$4 | $712 | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs